LogTrend's Complex Alarms Manual

[logo]

LogTrend

Copyright  2001 by LogTrend http://www.logtrend.org

This software and all affiliated files are Copyright (C) 2001 by Atrid Systmes
under the terms of the GNU General Public License. A copy of this license
entitled "GNU General Public License" is included with the software. The
original text can be found on http://www.gnu.org/copyleft/gpl.html

Permission is granted to copy, distribute and/or modify this document under the
terms of the GNU Free Documentation License, Version 1.1 or any later version
published by the Free Software Foundation; with no Invariant Sections , with no
Front-Cover Texts , and with no Back-Cover Texts. A copy of the license
entitled "GNU Free Documentation License" can be found with this software. The
original text can be found on http://www.gnu.org/copyleft/fdl.html

-------------------------------------------------------------------------------

Table of Contents
1. LogTrend's Complex Alarms
   
    Alarms in LogTrend
    Complex Alarms configuration file
       
        DataBase (required)
        Source, agent and number (required)
        Alarm level (required)
        Action (optional)
        Equation (required)
       
2. Complex Alarm Equations
   
    Logical operators
    Detection functions
    Standard detection function
       
        Examples of equation with duration
       
A. Complex Alarm tools

-------------------------------------------------------------------------------

Chapter 1. LogTrend's Complex Alarms

Alarms in LogTrend

There are two types of alarms in LogTrend : agents' binary alarms and complex
alarms. Agents' alarms are generated during the data collection. These alarms
are useful to know the state of a system in real time, but not sufficient to
carry out trends analysis. Trend analysis can be done by complex alarms. These
alarms are described by logical equations like : " if the cpu load is superior
to 90 % during two hours EXCEPT monday between 9 and 12."

These equations are logical operations (AND, OR, NOT) between functions, called
detection functions, applied to variables :
          superior(cpu, 90, 3600) AND inferior(cpu_system, 10, 3600)
        
superior and inferior are detection functions. cpu and cpu_system are
variables.

You can found a description of the standard detection functions in the section
called Standard detection function in Chapter 2.

-------------------------------------------------------------------------------

Complex Alarms configuration file

Like all LogTrend config files, Complex Alarms comfiguration file is an XML
file :
          
<ComplexAlarm>
          <DataBase Name="logtrend" Host="server.domain.fr" Port="5432" 
                    User="logtrend" Password="logtrend" />
          <Source>5</Source>
          <Agent>7</Agent>
          <Number>1</Number>
          <Name>CPU overload detection</Name>
          <Level>
            <Warning />
          </Level>
          <Action>
            <Xmessage Display=":0.0">Alarm</Xmessage>
            <Mail Address="me@mydomain.com" Subject="CPU Overloaded">
              The CPU is overloaded on myclient.mydomain.com
            </Mail>       
          </Action>
          <Equation>
            (superior(cpu, 90) AND inferior(cpu_system, 10)) AND duration(3600)
          </Equation>
        </ComplexAlarm>
          
        

-------------------------------------------------------------------------------

DataBase (required)

 
          
<DataBase Name="logtrend" Host="server.domain.fr" Port="5432"
          User="logtrend" Password="logtrend" />
          
        

The DataBase tag is used to set up LogTrend database connection parameters.
This tag has 5 attributes and contains no data.

Attributes (all is required, no default values) :

  * Name : Name of the database
   
  * Host : Name of the host where is the database
   
  * Port : Port of the database on the server
   
  * User : User name to connect to the database
   
  * Password : Password of this user
   
-------------------------------------------------------------------------------

Source, agent and number (required)

 
          
<Source>5</Source>
<Agent>7</Agent>
<Number>1</Number>
          
        

Each complex alarm is identifed by a source, an agent and a number. Each
complex alarm of an agent must have a different number.

-------------------------------------------------------------------------------

Alarm level (required)

 
          
<Level>
   <Warning />
</Level>
          
        

There are three levels for alarms :

  * Info : Not really an alarm, just an information
   
  * Warning : Not critical alarm.
   
  * Error : Critical alarm.
   
-------------------------------------------------------------------------------

Action (optional)

 
    
<Action>
  <Xmessage Display=":0.0">Alarm</Xmessage>
  <Mail Address="me@mydomain.com" Subject="CPU Overloaded">
    The CPU is overloaded on myclient.mydomain.com
  </Mail>         
</Action>
    
  

This tag describe actions launched when the alarm is raised. There four
standard actions. But you can develop customized action.

Available actions are :

-------------------------------------------------------------------------------

Mail

      
<Mail Address="me@mydomain.com" Subject="CPU Overloaded" Sender="sender@mydomain.com" SMTPServer="mysmtphost">
  The CPU is overloaded on myclient.mydomain.com
</Mail>
      
    

Send a mail to Address with subject subject. If specified, SMTPServer is used.
Sender is used in the From field of the mail. By default, Sender is equal to
Address.

-------------------------------------------------------------------------------

SMS

      
<SMS NationalPhone="0612345678" InternationalPhone="+33612345678">
   System overloaded
</SMS>
      
    

Send a message to a cellular phone. Phone number must be specified in national
and international format.

    Note: Currently, SMS Sender uses free web sites to send messages. This
    method does not really work because it depends of web site structure that
    change frequently. This action will be soon reimplemented to used more
    reliable methods like GSM modem.
   
-------------------------------------------------------------------------------

Syslog

      
<Syslog>System overloaded</Syslog>
      
    

Add a message in system logs with Syslog

-------------------------------------------------------------------------------

Execute

      
<Execute>/usr/local/bin/myscript.pl</Execute>
      
    

Run an external command line.

-------------------------------------------------------------------------------

Xmessage

      
<Xmessage Display=":0.0">Alarm</Xmessage>
      
    

Display a message in a X Window. This action is very usefull while debugging.

-------------------------------------------------------------------------------

Equation (required)

            
<Equation>
   (superior(cpu, 90) AND inferior(cpu_system, 10)) AND duration(3600)
</Equation>
            
        

Contains the complex alarm equation, see Chapter 2 for more detail.

-------------------------------------------------------------------------------

Chapter 2. Complex Alarm Equations

As I said above, complex alarm equations are logical operations between
detection functions :
        (superior(cpu, 90) AND inferior(cpu_system, 10)) AND duration(3600)
      
Above equation stand for : "if the cpu is up to 90 % and cpu used by the system
inferior to 10 % during 1 hour." It's possible to do more complex equation with
parenthesis like :
        (f1() AND f2()) OR (NOT f4() OR f5() AND f6())
      

-------------------------------------------------------------------------------

Logical operators

There are three logical operators available : AND, OR and NOT. Priorities are
classical : NOT has priority on AND and AND has priority on OR.

Detection functions return tabulars of data, one tabular by variable. In this
tabular, there are couple of (value, date). AND, OR and NOT do intersection,
union and inverting of these tabulars. An equation is true if the result is a
non empty tabular.

    About NOT operator: Note that the NOT does not work like a boolean NOT but
    like a binary NOT. It return all values which was in initial values tabular
    and NOT in the result return by the function.
   
-------------------------------------------------------------------------------

Detection functions

Detection functions can take several arguments :
function_name(arg1, arg2, arg3)
Some of these arguments can be variable names. Variable names are name of
agents data in lowercase with _ instead of spaces and wihout characters between
parenthesis.

Examples :

  * "Cpu System" became cpu_system
   
  * "Received bytes on eth0 (192.168.10.47)" became received_bytes_on_eth0
   
You can have the list of agents data names with GetListfVariables (see Appendix
A for more details on Complex Alarm tools).

It's possible to build equation using variable of differents agents :
          var_name[source_number, agent_number]
        
Default values for source and agent are value of <Source> and <Agent> tags of
the complex alarm description file.

Example :
          function1(var1[2, 5]) AND function2(var2[9, 1]) AND function3(var3)
        

You can do arithmetic operations between variables or number :
          function1(var1 + var2, (10+8)/5, 15) AND function2((var3+var4[5, 6])/2)
        

-------------------------------------------------------------------------------

Standard detection function

superior( variable limit [duration] );

Return value of variable superior to limit. If duration is present, superior
return all values suites superior to limit during at least duration seconds.

inferior( variable limit [duration] );

Return value of variable inferior to limit. If duration is present, inferior
return all values suites inferior to limit during at least duration seconds.

equal( variable limit [duration] );

Return value of variable equal to limit. If duration is present, equal return
all values suites equal to limit during at least duration seconds.

different( variable limit [duration] );

Return value of variable not equal to limit. If duration is present, different
return all values suites not equal to limit during at least duration seconds.

between( variable lower_bound upper_bound [duration] );

Return value of variable between lower_bound and upper_bound. If duration is
present, between return all values suites between lower_bound and upper_bound
during at least duration seconds.

average( variable duration comp_func comp_func_args );

Return the average on duration seconds for each data of variables, and apply
the comparison function comp_func to the result. comp_func should be one of
superior, inferior, equal, different and between.

duration( duration );

This function is very particular. duration is not apply to a particular
variable but to all variables used in the equation. duration look for a suite
of value with continuous date. The sentence which describe when this function
can be used is : "during X seconds".

Example :
          (superior(cpu, 90) AND inferior(cpu_system, 10)) AND duration(3600)
        
This equation stand for : "when cpu is greater than 90 % AND cpu_system lower
than 10 % during 3600 seconds.

+-----------------------------------------------------------------------------+
|                                   Warning                                   |
+-----------------------------------------------------------------------------+
|This is not the same thing than :                                            |
|              superior(cpu, 90, 3600) AND inferior(cpu_system, 10, 3600)     |
|                                                                             |
|In this equation, it's not mentionned that superior and inferior must be true|
|during the same 3600 seconds                                                 |
+-----------------------------------------------------------------------------+
There are more examples with duration in the section called Examples of
equation with duration.

time_interval( start_date end_date );

Return the data having a date between start_date and end_date Dates are strings
like "friday 14 september 2001 13 hours 00 minutes 00 seconds" or "fri 14 sep
2001 13 h 00 m 00 s" or "14/09/2001 13:00:00". Hours is in 24 hours formats.

Dates are not necessary absolute. Examples :

  * "Tue 24 april 2001 9 hours 24 min 30 sec"
   
  * "24 april" : each 24 april
   
  * "24" : the 24th of each month
   
  * "24 10 hours" : the 24th of each month at 10
   
  * "2000" : the data of the year 2000
   
  * "9 h 24 m" : each day at 9h 24
   
    Note: Unlike duration you can write NOT time_interval(date1, date2) to
    exclude a time interval
   
-------------------------------------------------------------------------------

Examples of equation with duration

  * f1(var1) AND duration(120) AND f2(var2) : duration just affect f1 and not
    f2. It's equivalent to : (f1(var1) AND duration(120)) AND f2(var2)
   
  * f1(var1) AND f2(var2) AND duration(120) : duration just affect f2 and not
    f1. It's equivalent to : (f2(var2) AND duration(120)) ANDf1(var1)
   
  * (f1(var1) AND f2(var2)) AND duration(120) : Thank to parenthesis, duration
    is applyed to f1(var1) AND f2(var2)
   
  * duration(120) AND f2(var2) : This does not make any sense. There is nothing
    to compare where duration is ran.
   
  * (superior(cpu, 90) AND inferior(cpu_system, 10)) AND NOT duration(3600) :
    This does not make any sense. You should write : NOT ((superior(cpu, 90)
    AND inferior(cpu_system, 10)) AND duration(3600))
   
  * (superior(cpu, 90) AND inferior(cpu_system, 10)) OR duration(3600) : This
    does not make any sense. OR cancel duration.
   
-------------------------------------------------------------------------------

Appendix A. Complex Alarm tools

BuildDescFileSquel [--database database_name] [--host host_name] [--port
server_port] filename.xml
[--help]

Tool to build new complex alarm description files.

ComplexAlarm [--register] [--frequency freq] [--daemon] filename...
[--help]

Run or register complex alarms.

  * With --register, register complex alarms in database.
   
  * --frequency specify the time in minutes between 2 alarms check.
   
  * filename can be a directory name
   
GetSourcesList [--database database_name] [--host host_name] [--port
server_port] [--help]

Return the list of the source on the specified database.

GetListOfAgentsOnSource --source source_number [--database database_name]
[--host host_name] [--port server_port] [--help]

Return the list of agents of a source.

GetListOfVariables --source source_number --agent agent_number [--database
database_name] [--host host_name] [--port server_port] [--help]

Return the variable names list of an agent.